[root@localhost /]# hpacucli
HP Array Configuration Utility CLI 9.40.12.0
Detecting Controllers...Done.
Type "help" for a list of supported commands.
Type "exit" to close the console.
=> ctrl all show config
Smart Array P410i in Slot 0 (Embedded) (sn: 5001438006EFBFC0)
array A (SAS, Unused Space: 0 MB)
logicaldrive 1 (1.6 TB, RAID 5, OK)
physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SAS, 300 GB, OK)
physicaldrive 1I:1:6 (port 1I:box 1:bay 6, SAS, 300 GB, OK)
physicaldrive 1I:1:7 (port 1I:box 1:bay 7, SAS, 300 GB, OK)
physicaldrive 2I:1:1 (port 2I:box 1:bay 1, SAS, 300 GB, OK)
physicaldrive 2I:1:2 (port 2I:box 1:bay 2, SAS, 300 GB, OK)
physicaldrive 2I:1:3 (port 2I:box 1:bay 3, SAS, 300 GB, OK)
physicaldrive 2I:1:4 (port 2I:box 1:bay 4, SAS, 300 GB, OK)
unassigned
physicaldrive 1I:1:8 (port 1I:box 1:bay 8, SAS, 300 GB, OK)
SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 (WWID: 5001438006EFBFCF)
=> ctrl slot=0 array all add spares=1I:1:8
=> ctrl all show config
Smart Array P410i in Slot 0 (Embedded) (sn: 5001438006EFBFC0)
array A (SAS, Unused Space: 0 MB)
logicaldrive 1 (1.6 TB, RAID 5, OK)
physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SAS, 300 GB, OK)
physicaldrive 1I:1:6 (port 1I:box 1:bay 6, SAS, 300 GB, OK)
physicaldrive 1I:1:7 (port 1I:box 1:bay 7, SAS, 300 GB, OK)
physicaldrive 2I:1:1 (port 2I:box 1:bay 1, SAS, 300 GB, OK)
physicaldrive 2I:1:2 (port 2I:box 1:bay 2, SAS, 300 GB, OK)
physicaldrive 2I:1:3 (port 2I:box 1:bay 3, SAS, 300 GB, OK)
physicaldrive 2I:1:4 (port 2I:box 1:bay 4, SAS, 300 GB, OK)
physicaldrive 1I:1:8 (port 1I:box 1:bay 8, SAS, 300 GB, OK, spare)
SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 (WWID: 5001438006EFBFCF)
=>